Professional Transformer & Inductor Manufacturer
Toroidal Transformer

Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise

TT is the series name, not a single model. This material covers a toroidal power transformer wound with copper wire on a grain-oriented silicon steel ring core, with a power range of 20 VA to 1500 VA, operating frequency 50 Hz or 60 Hz, primary 220 V, led out with two red leads, and secondary with two blue leads. As the secondary is wound to order, the VA rating is the only parameter that remains constant throughout the series; the corresponding voltage and current vary with each manufacturing run.

额定功率范围
20 VA to 1500 VA
额定功率范围 (2)
20 VA to 1500 VA
次级
蓝-蓝,定制

View all specifications →

Description

1. Product Name

TT is the series name, not a single model. This series covers a toroidal power transformer wound with copper wire on a grain-oriented silicon steel ring core, with a power range of 20 VA to 1500 VA, operating frequency 50 Hz or 60 Hz, primary 220 V, led out with two red leads, and secondary with two blue leads. As the secondary winding is custom-wound to order, the VA rating is the only parameter that remains constant throughout the series; the corresponding voltage and current vary with each manufacturing run.

The model designation follows the pattern: TT, VA rating, primary voltage, secondary voltage. TT1000-220-24 indicates a 1000 VA specification with primary 220 V and secondary 24 V; TT50-220-24 indicates the same construction for a 50 VA specification. Please treat this as a general pattern for model identification rather than a published coding rule, and provide the full model when ordering.

2. Core and Construction

The core is formed by winding grain-oriented silicon steel strip into a ring and bonding it, creating a closed circular magnetic path with no air gap, and the grain direction aligns with the flux path. This achieves three advantages impossible with laminated cores: eliminating the air gap required when cutting the core; confining the magnetic field within the ring so minimal flux leaks to the surroundings; and eliminating the loose lamination stack that would hum at twice the mains frequency. The supplier panel indicates grain-oriented silicon steel and pure copper wire but does not specify the exact grades of either.

The winding is distributed evenly around the entire ring rather than concentrated on one side, which allows the copper wire to cover the full circumference and shorten the average turn length. Each winding is led out as a pair of insulated leads with protective sleeves at the exit point. The finished toroidal transformer is first wrapped with white tape, then wrapped in transparent film, and finally secured to the base plate with a bolt. The copper wire can be seen through the film between the outer wrapping and the core, as shown in the close-up view.

TT Series Toroidal Power Transformer, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise 11
Winding detail: tightly packed copper turns beneath the outer wrapping

3. Windings and Leads

The primary is led out with two leads, and the secondary with two leads. On the 150 VA unit, the label reads “Input 0 V - 220 V” for the red lead pair and “Output 0 V - 60 V” for the blue lead pair, both applicable for 50 Hz or 60 Hz; the 300 VA unit has the same layout with an output of 0 V - 66 V. Throughout the series, red indicates the primary and blue the secondary. Leads exit with protective sleeves rather than terminated ends, so the product leaves the factory without any connectors, terminals, or ferrule terminals.

TT Series Toroidal Power Transformer, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise 12
Lead exit: sleeved red and blue leads, with a central through-bolt with nut and washer
Two points must be confirmed regarding the lead ends. Lead length is shown only by a dimension line on the drawing, with no numerical value, so the length must be specified with the order. Additionally, no terminals are installed: the lead ends are cut, and connections are made inside the chassis rather than on the transformer.

4. Mounting Method

The toroidal transformer is mounted on a black painted steel base plate larger than the coil, with mounting holes at four corners, and secured from top to bottom through a central hole with a bolt, nut, and washer set. This central fixing ensures the core remains compressed and prevents movement; the four corner holes are used to fasten the base plate to the chassis bottom or side panels. Base plate dimensions, hole diameters, bolt threads, and washer set heights are not specified in the material.

5. Electrical Parameter Range

The table serves as the basis for product selection. Each row corresponds to one rating and is also the only place where the windings are described. Each row specifies a dielectric withstand test of 2500 V DC applied from primary to secondary, with insulation resistance nominally not less than 500 megohms; therefore, these two columns need only be noted once rather than repeated fifteen times. No-load core loss is the only published loss parameter: efficiency, voltage regulation, temperature rise, and leakage inductance are not listed.

TT Series Toroidal Power Transformer, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise 13
Supplier drawing and specification table; outer diameter, inner diameter, height, and lead length are indicated but values are not printed

5.1 Published Ratings

PowerNo-Load Secondary VoltageFull-Load CurrentCore Loss
20 WAC12.0V ±2%1.66 A<0.9 W
40 WAC12.5V ±2%3.3 A<2.0 W
50 W [230 V]AC5-0-5V ±2%5.0 A<2.0 W
70 W [230 V]AC14.5V ±2%5.0 A<3.0 W
90 WAC28+9+16V, printed symbol repeated, see note below2.1+1.7+1 A<3.0 W
120 WAC20-20-80-100V+1V ±2%6 A<3.0 W
150 WAC22V ±2%6.8 A<3.0 W
200 WAC12V x 2, ±2%8.4 A<4.0 W
240 WAC24V ±2%10 A<4.0 W
300 WAC24.5V ±2%12.5 A<5.0 W
400 WAC70.5V ±2%5.7 A<6.0 W
500 WAC36V ±2%13.9 A<4.5 W
1000 W [240 V]AC36.5V ±2%27.5 A<10 W
1200 WAC45+36V ±2%13.3+16.6 A<12 W
1500 W [415 V]AC48V ±2%31.2 A<20 W
Except for the four models with bracketed voltage labels, the input voltage for all other rows is 220 V ±10%; the four exceptions are labeled 230 V, 240 V, and 415 V. This contradicts the supplier footnote stating that all values are typical at 220 V, so the input voltage for these four models must be confirmed. Two rows are reproduced as originally printed and are difficult to read: the 90 W row has a repeated tolerance symbol after 28+9+16V, which cannot represent two tolerances simultaneously; the 120 W row has four numbers 20, 20, 80, and 100, followed by +1V and ±2%, without indicating whether these are taps or two windings.

5.2 Two Clearly Labeled Units

The nameplates in the photos of two units are clearly legible. Both connect 220 V to the red lead pair; the secondary voltages are 60 V and 66 V, respectively, neither matching the 24 V series photos or the table row for the same VA rating. The power ratings match, but the windings are inconsistent.

Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary as Required, Low Noise 14
Rating plate, 150 VA unit: Input 0 V - 220 V red-red, Output 0 V - 60 V blue-blue, 50/60 Hz
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary as Required, Low Noise 15
Rating plate, 300 VA unit: Input 0 V - 220 V, Output 0 V - 66 V

6. Model Range

All products in the series photos are the same series with the same secondary voltage: all eleven clearly readable plates indicate 24 V, ranging from 50 VA/2.1 A to 1500 VA/62.5 A. Each current value is the rated power divided by 24 V, which is the basis for confirming the series rather than relying on any single plate. The smallest unit carries a TT-20 plate but is too small to read at this resolution and is not listed in the table. Each rating in the table corresponds to a different secondary voltage: the two panels represent the same platform with two different winding sets.

Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary as Required, Low Noise 16
Series photos, TT-20 to TT-1500, every clearly readable plate shows a 24 V secondary

6.1 24 V Series

ModelRated PowerSecondary VoltageCurrent
TT-5050 VA24 V2.1 A
TT-100100 VA24 V4.2 A
TT-150150 VA24 V6.3 A
TT-200200 VA24 V8.3 A
TT-300300 VA24 V12.5 A
TT-400400 VA24 V16.7 A
TT-500500 VA24 V20.8 A
TT-600600 VA24 V25 A
TT-800800 VA24 V33.3 A
TT-10001000 VA24 V41.7 A
TT-15001500 VA24 V62.5 A
The photos and the table are not from the same batch of products. The photos show the 24 V series, including 600 VA and 800 VA models, but the table has no corresponding rows; the table includes ratings from 20 W to 240 W, but the photos show no corresponding plates. The electrical parameters follow the table; the physical series follows the photos.

7. Quality and Compliance

The compliance panel displays CE, UL, RoHS, and CCC marks, with a statement below indicating compliance with global safety standards. The 150 VA plate also carries two square marks and a warning triangle. None of these marks are accompanied by certificate numbers, standard references, or test reports, so they are recorded here as marks and statements rather than certified facts. The only expressly specified test is the dielectric withstand test, which is 2500 V DC, not AC.

Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary as Required, Low Noise 17
Compliance panel with CE, UL, RoHS, and CCC marks
ItemDescriptionRemarks
Dielectric Withstand Test2500 V DC, primary to secondaryAll ratings, AC rather than DC
Insulation Resistance500 megohms or moreSame conditions as the withstand test
CEMark displayedNo certificate number
ULMark displayedNo certificate number
RoHSMark displayedReport not reproduced
CCCMark displayedNo certificate number

8. Characteristics

Toroidal core with no air gap.The strip is wound closed, so there is no air gap in the flux path, eliminating the need for excitation current.

Low leakage flux.The magnetic field is confined within the ring, so a toroidal transformer can be placed adjacent to signal-level circuits, whereas a laminated transformer would produce hum interference.

No lamination hum.The wound ring has no loose laminations, so mechanical noise at twice the mains frequency is absent from the start.

Same platform, 20 VA to 1500 VA.The same construction and mounting method apply from the smallest unit to the 1500 W rating.

Secondary wound to order.Voltage, current, taps, and the number of secondary windings are determined by the order, so the same VA value can correspond to multiple voltages.

9. Advantages

Core loss stated explicitly, not implied.Most catalog pages stop at merely listing the VA value. Here, each rating includes its own no-load core loss, which determines the operating temperature of a sealed enclosure.

Insulation clearly specified at both ends.The 2500 V DC withstand test and insulation resistance of 500 megohms or more apply to every row, making the insulation barrier an explicit requirement rather than a recommendation of good practice.

Series product, not a single specification.The fifteen ratings in the table and the eleven units in the series photos cover chassis designs, allowing expansion without changing the mounting method or lead color code.

Mounting hardware pre-installed.The base plate and center bolt are supplied with the product, so the chassis only needs a flat surface and four holes, eliminating the need to design brackets around the transformer.

Fixed core, custom winding.Since only the winding changes between batches, a second voltage requires only changing the winding on a known core, a shorter path than a completely new design.

10. Specifications

Values are transcribed from supplier panels. Where missing, they are marked “not specified”; where the material contradicts itself, the contradiction is pointed out rather than resolved.

10.1 Overview

ItemSpecificationRemarks
ProductTT series toroidal power transformerSeries product, wound to order
WindingCopper wire, evenly distributed around the toroidal coreWire grade not specified
Rated Power20 VA to 1500 VAFifteen ratings in total in the table
Primary220 V, two red leadsFour rows list other input voltages
SecondaryTwo blue leads, wound to orderVoltage varies by batch
Frequency50 Hz / 60 HzApplicable to every row
InsulationWithstand test 2500 V DC, 500 megohms or morePrimary to secondary
MountingSteel base plate, center through-boltBase plate dimensions not specified
WeightNot specifiedNo data anywhere in the material

10.2 Mechanical Parameters

ItemSpecificationRemarks
CoreWound silicon steel ringGrain-oriented, no air gap
Outer WrapWhite tape under transparent filmMaterial grade not specified
LeadsRed primary pair, blue secondary pairSleeved at exit
TerminationNot installedLeads are cut at the factory
Base PlatePainted steel, holes at four cornersDimensions and hole diameters not specified
Center FixingBolt, nut, and washer through the center holeThread specification not specified
Lead LengthNot specifiedShown only as dimension lines, no values
Overall DimensionsNot specifiedOuter diameter, inner diameter, and height are only symbols
The drawing is a definition, not a dimensioned drawing. It indicates outer diameter, inner diameter, height, and lead length, but none are quantified, so chassis layout cannot be designed from this material alone. Weight is also missing, which becomes critical once the part is mounted on a panel rather than on the floor.

11. Applications

The following uses are categories listed by the supplier for this series, accompanied by a brief explanation of why a toroidal transformer suits each use. They describe the fields in which the series is marketed, not certification of any specific product.

Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise 18
Supplier panel: toroidal transformer mounted in an amplifier chassis, labeled low noise, high efficiency

Audio amplifiers.The photo on this page shows a toroidal transformer inside an amplifier next to storage capacitors, a classic application: low leakage flux prevents hum from entering the signal path.

Medical power supplies.Isolated power supplies require documented high-voltage test results, and housings are often sealed, so core loss matters more than efficiency.

Industrial power supplies.Control and drive power supplies require compact isolated supply rails and a mounting plate rather than mounting brackets.

Renewable energy and inverter stages.Auxiliary power and gate drive power supplies inside inverter and converter cabinets.

Instrumentation and test equipment.Bench and rack-mount power supplies where the transformer is placed close to low-level circuits.

12. Ordering

Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise 19
Packaging: six toroidal transformers per carton with molded foam padding

Please provide winding parameters, not just the VA value. A valid inquiry should include the rated power, primary voltage, secondary voltage or list of secondary windings, frequency, desired lead length, whether the base plate and center bolt are required, and quantities per order and per delivery. With this information, the core, wire, turns, and base plate can be determined, and pricing follows. If a chassis already exists, provide the envelope dimensions and mounting hole layout that must be accommodated so that the base plate can be verified before winding begins.

Regarding compliance: the nameplate shows CE, UL, RoHS, and CCC marks and declares compliance with global safety standards. No certificate numbers, standard references, or test reports appear on the nameplate, so these are marks and statements rather than certified facts. The only expressly specified test is a 2500 V DC high-voltage test, with insulation resistance of 500 megohms or more. If your equipment must comply with a particular standard, request certificates and test reports before selecting the design.

Scope of this page. Fifteen rated powers with their input and no-load voltages, currents and core losses, 2500 V DC high-voltage test, 500 megohm insulation resistance, 50 Hz and 60 Hz data, eleven 24 V labels, and two 60 V and 66 V rating labels are transcribed from supplier nameplates. Dimensions, hole diameters, heights, lead lengths, weights, base plate sizes, bolt threads, wire and core grades, efficiency, regulation, temperature rise, and pricing are not provided and are left blank rather than estimated. Three provided images are not reproduced: two are duplicate views already in the library, and one is a bench nameplate whose statements are described in the text above.

Brand/Manufacturer: ZXY, Shenzhen Zhi Xiang Yuan Electronics Co., Ltd. http://www.zxycoil.com

Specifications

Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise · Specifications
额定功率范围20 VA to 1500 VA
额定功率范围 (2)20 VA to 1500 VA
次级蓝-蓝,定制
制造商Shenzhen Zhixiangyuan Electronics Co., Ltd.
耐压测试直流 2500 V 初级至次级
绝缘电阻500兆欧或以上
初级220 V,红-红
系列TT环形电源变压器
频率50 Hz / 60 Hz
安装方式钢底板,中心螺栓
品牌ZXY

Only supplied parameters are shown. Please confirm any unlisted electrical performance, test conditions, tolerances and customization options with our engineers. The final specification sheet takes precedence.

Product Images & Drawings

View the available product images and drawings below. Click to open the original. Customized products are subject to the agreed specifications and drawings.

Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise — Product Images & Drawings1
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise · 1View Original
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise — Product Images & Drawings2
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise · 2View Original
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise — Product Images & Drawings3
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise · 3View Original
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise — Product Images & Drawings4
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise · 4View Original
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise — Product Images & Drawings5
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise · 5View Original
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise — Product Images & Drawings6
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise · 6View Original
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise — Product Images & Drawings7
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise · 7View Original
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise — Product Images & Drawings8
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise · 8View Original
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise — Product Images & Drawings9
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise · 9View Original
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise — Product Images & Drawings10
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise · 10View Original
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise — Product Images & Drawings11
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise · 11View Original
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise — Product Images & Drawings12
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise · 12View Original
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise — Product Images & Drawings13
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise · 13View Original
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise — Product Images & Drawings14
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise · 14View Original
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise — Product Images & Drawings15
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise · 15View Original
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise — Product Images & Drawings16
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise · 16View Original
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise — Product Images & Drawings17
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise · 17View Original
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise — Product Images & Drawings18
Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise · 18View Original

Downloads

No specification sheet has been uploaded for this model yet. Use the inquiry form below to request parameters, dimension drawings or sample information.

Selection & Customization Requirements

To help confirm a suitable model and specification, please provide:

  • Your equipment, application, operating environment and temperature range.
  • As applicable: inductance, turns ratio or impedance, operating frequency, voltage, current and insulation requirements.
  • Size limits, mounting method, pin spacing, and any existing drawings or reference samples.
  • Sample quantity, estimated order volume and desired delivery date.
Request Specifications / Selection Support

Frequently Asked Questions

Common procurement questions about Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise.

What is Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise?

TT is the series name, not a single model. This material covers a toroidal power transformer wound with copper wire on a grain-oriented silicon steel ring core, with a power range of 20 VA to 1500 VA, operating frequency 50 Hz or 60 Hz, primary 220 V, led out with two red leads, and secondary with two blue leads. As the secondary is wound to order, the VA rating is the only parameter that remains constant throughout the series; the corresponding voltage and current vary with each manufacturing run.

Can Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise be customized to our specifications?

Yes. Shenzhen ZhiXiangyuan Electronics Co., Ltd. provides OEM/ODM services. Inductance, turns ratio, current rating, core material, size and terminal style can all be customized according to your drawings or samples.

What is the MOQ and lead time for Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise?

MOQ is negotiable based on the specific model and order quantity. Typical lead time is 1-3 weeks for standard items and 2-4 weeks for customized orders. Contact our sales team for an exact quotation.

Do you provide samples of Toroidal Power Transformer TT Series, 20 VA to 1500 VA, 50/60 Hz, 220 V Primary, Custom Secondary, Low Noise?

Yes, samples are available for evaluation before bulk orders. Please send us your requirements and shipping details to request samples.

Send Us a Message

Tell us your requirements and our engineers will reply within 24 hours.