Professional Transformer & Inductor Manufacturer
Toroidal Transformer

RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount

ModelRY-800VACategoryToroidal Transformer

RY-800VA is the model number on the nameplate, which carries all identifying information for this component: the primary is red leads, AC 220 V 50 Hz; secondaries are 0 V to 38 V between yellow-yellow wires, and 0 V to 38 V between blue-blue wires; it carries a 130 degrees C thermal marking and a date stamp. The same nameplate also bears CCC, CE and WEEE marks and a double insulation symbol. No drawing is included in the material, so the nameplate serves as the datasheet.

型号
RY-800VA
型号(2)
RY-800VA
热保护
130摄氏度切断

View all specifications →

Description

1. Product Name

RY-800VA is the model number on the nameplate, which carries all identifying information for this component: the primary is red leads, AC 220 V 50 Hz, secondaries are 0 V to 38 V between yellow-yellow leads and 0 V to 38 V between blue-blue leads, with a 130°C thermal cutoff marking and date stamp. The same nameplate also bears CCC, CE and WEEE marks and a double insulation symbol. No drawing is included, so the nameplate serves as the datasheet.

The panel describes the same component in three ways: as a toroidal transformer in the 50 VA to 1000 VA series, as an audio-grade transformer, and as an 800 VA custom product. These are three angles on the same product line. The component itself is a power transformer, not an output transformer: the secondary windings power a rectifier and filter capacitors, and audio signals never pass through it.

RY-800VA 800VA 环形音频电源变压器 AC 220V 50Hz 双次级中心螺栓安装 10
Specification panel: model, input, two outputs and 130°C cutoff protection

2. Functional Description

There are two reasons to choose a toroidal transformer in audio equipment. The core is a continuous ring, so the magnetic circuit has no air gap, and its external leakage field is smaller than that of an EI-laminated transformer of the same power rating; this allows it to be mounted close to signal stages inside the chassis. The windings cover the entire core, so for the same power rating the component is shorter and wider than a laminated type, suitable for slim chassis. Two independent secondary windings with two colour-coded lead sets provide two isolated outputs, so a dual supply rail can be built with two bridge rectifiers and one transformer.

This places two requirements on chassis design. The bolt is the mounting method, so the bottom plate needs a centre hole; the four slots on the base plate are for anti-rotation screws, not for load bearing. Toroidal transformers have high inrush current at switch-on, so the power switch and fuse must be selected accordingly, not just by the 800 VA rating.
RY-800VA 800VA 环形音频电源变压器 AC 220V 50Hz 双次级中心螺栓安装 11
Application in a power amplifier: the RY-800VA transformer sits on the chassis base plate next to filter capacitors

3. Construction and Windings

The manufacturing process is visible in the close-up images. Oxygen-free copper wire is wound on a seamless grain-oriented silicon steel core using radial winding, i.e. coils stand upright around the ring rather than being stacked flat, which shortens the winding length and reduces resistance. Paper and film insulation separate the windings, leads are brought out as flying leads, and the entire toroidal transformer is wrapped in transparent high-voltage insulation film, visible in the close-up as a glossy coating over the copper wire.

RY-800VA 800VA 环形音频电源变压器 AC 220V 50Hz 双次级中心螺栓安装 12
Supplier panel: oxygen-free copper radial winding on grain-oriented silicon steel core
RY-800VA 800VA 环形音频电源变压器 AC 220V 50Hz 双次级中心螺栓安装 13
Winding close-up: copper radial winding under transparent high-voltage insulation

4. Centre Bolt Mounting

Mounting uses a single centre bolt. A black steel top plate is pressed onto the toroidal transformer, and a galvanised bolt passes through the plate and core; a nut with rubber washer and steel washer clamps the assembly. The rubber breaks the metallic path between the bolt and the top plate, preventing chassis vibration from entering the core and also preventing core vibration from being transmitted to the chassis. The toroidal transformer sits on a black base plate with four slots at the corners for fixing screws; the base plate shape allows the component to be rotated to route leads where needed.

RY-800VA 800VA 环形音频电源变压器 AC 220V 50Hz 双次级中心螺栓安装 14
Bolt close-up: galvanised centre bolt and nut with vibration-damping washer and spacer below
RY-800VA 800VA 环形音频电源变压器 AC 220V 50Hz 双次级中心螺栓安装 15
Supplier panel: heavy-duty centre bolt mount with rubber washer annotation

5. Electrical Specifications

The specification panel gives five lines of parameters, repeated on the nameplate. Model RY-800VA, 800 VA. Input AC 220 V 50 Hz, red-red leads. Output 1, AC 0 V to 36 V, yellow-yellow leads. Output 2, AC 0 V to 36 V, blue-blue leads. Thermal protection, 130°C cutoff. In some photos, the nameplate on the part itself labels both secondaries as 0 V to 38 V, while another photo shows 0 V to 36 V; this is the only inconsistency in the material.

5.1 Published Parameter Set

ParameterValueRemarks
ModelRY-800VALocated on nameplate and control panel
Rated power800 VAOnly power value given
InputAC 220 V, 50 HzRed-red leads
Output 1AC 0 V to 36 VYellow-yellow leads, per spec panel
Output 2AC 0 V to 36 VBlue-blue leads, per spec panel
Nameplate outputAC 0 V to 38 VThree labels read 38 V, one reads 36 V
Thermal protection130°C cutoffMarked on nameplate and noted on panel
Current per secondaryNot statedSee notes for derived value
The difference between 38 V and 36 V is not superficial. After rectification and smoothing, the DC bus voltage is roughly 1.4 times the AC value, so these two readings can shift the bus voltage by several volts and change the power the amplifier can deliver before clipping. The page neither states the current per secondary nor the voltage regulation, so the loaded bus voltage cannot be derived from the page. Before designing the power supply, request winding details or measure a sample under load.

6. Bench Measurement

A photo shows the device connected to a power analyzer with the primary winding connected: RMS 229.7 V, RMS current 0.151 A, power 34.70 W, power factor 0.996, behind it are oscilloscope waveforms of primary voltage and current. The room mains voltage is higher than the 220 V rating, and 34.70 W is about 4% of the 800 VA rating, so this is a light-load reading, not a full-load test. It shows the device operates at normal current with a clean current waveform in phase with the voltage; but no efficiency, voltage regulation or temperature rise is given.

RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 16
Bench check: power analyzer reads 229.7 V, 0.151 A, 34.70 W, power factor 0.996
Treat this reading as evidence that the device operates normally, not as a datasheet parameter. There is no load description in the view, nor are secondary windings connected, and the power factor near 1 with only 4% load is not typical of an unloaded transformer. If the design cares about no-load current, efficiency or voltage regulation, obtain these three values under specified load and specified mains voltage.

7. Audio Performance and Series

The audio performance description on the panel is qualitative: ultra-low leakage flux, low mechanical noise, high current capacity and fast dynamic response. These descriptions give no numbers or test conditions, and the panel showing them is a 50 W 24 V product from the same series, not the 800 VA device, so they describe structural and series characteristics rather than this power rating. The series published range is 50 VA to 1000 VA, supporting single and dual outputs, as well as OEM or ODM manufacturing, with two series labels reading EEEIO-C50VA and EEEIO-C100VA, which differ from the RY-800VA prefix.

RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 17
Supplier panel: high-fidelity audio-grade description shown on a 50 W 24 V product from the same series
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 18
Supplier panel: toroidal series 50 VA to 1000 VA, single and dual outputs
Treat the audio performance descriptions as design intent, not measured results. Leakage field, hum and dynamic response can be requested from the manufacturer on samples, but none are quantified here. The set of images is a product series photo, and its labels belong to other ratings, so it cannot prove any characteristic of the 800 VA product.

8. Packaging and Delivery

Supply form is a carton with moulded EPE foam lining, described as a heavy-duty carton that has passed drop testing. A photo shows six products standing in foam inside one carton, which is the shipping method for this series, not a statement of quantity per carton for this rating. No quantity, carton size or weight is given.

RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 19
Supplier panel: export packaging, moulded EPE foam lining in heavy-duty carton

9. Quality and Compliance

The compliance panel shows four marks: CCC, CE, RoHS and UL, headed 'International Quality Certification and Standards', with a top line stating that all four cover this device. The nameplate itself carries CCC, CE, a double-square insulation symbol, a moisture-proof umbrella symbol and a WEEE bin symbol. None of the marks is accompanied by certificate numbers, standard references or reports, and the UL mark does not show the 'Recognized' wording usually associated with component certification.

RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount 20
Compliance panel: CCC, CE, RoHS and UL marks; nameplate readable on the device
ItemDescriptionRemarks
Thermal cutoff130°CNoted on nameplate and panel
Dielectric testNot statedTest voltage not published
Insulation resistanceNot statedNot published
CCC certificationMark presentNo certificate number
CE certificationMark presentNo certificate number
RoHS and UL certificationMark presentNo certificate number, UL does not show "Recognized" mark

10. Features

800 VA toroidal transformer. Two secondary windings on a single core, wound to the rated power, while retaining the low-profile shape characteristic of toroidal transformers at this power.

Two isolated secondary windings. Yellow-yellow and blue-blue leads, each 0 V to 36 V or 38 V (as per nameplate), so a single device can provide dual supply rails.

130°C thermal cutoff. A thermal element embedded in the winding, marked on the nameplate and identified as a protection device on the specification panel.

Oxygen-free copper, radial winding. Windings stand upright along the core edge, shortening turn length and reducing resistance.

Grain-oriented silicon steel core. Seamless silicon steel ring with no air gap in the magnetic circuit, effectively reducing leakage flux.

Centre bolt with rubber buffer. One bolt passes through the core to fix the device to the chassis base plate, with a rubber buffer and steel washer between the bolt and top plate.

11. Advantages

Can be installed inside the chassis. The toroidal transformer at this power rating is low and wide, with minimal leakage flux, so it can be mounted close to the input stage without introducing AC hum.

One device, dual supply rails. Two isolated secondary windings eliminate the second transformer usually required in dual-supply designs.

The bolt is the mounting method. The base plate needs only one mounting hole and four anti-rotation screws, no base or bracket required.

Rubber buffer is the quiet guarantee. It breaks the metallic path between the bolt and base plate, preventing core vibration from reaching the chassis.

Published power range. The same construction covers the full 50 VA to 1000 VA series; changing supply rails only requires changing the winding, not a redesign.

12. Technical Specifications

All values are transcribed from the supplier's specification panel and nameplate. When a value is missing, the cell is marked 'Not stated'. When two nameplates disagree, both readings are retained; conflicts are noted in the remarks column rather than resolved here.

ItemSpecificationRemarks
ProductToroidal audio power transformerPower transformer, not an output transformer
ModelRY-800VAPrinted on nameplate
Rated power800 VAWinding rating, not actual DC output value
InputAC 220 V, 50 HzRed-red leads
Output 1AC 0 V to 36 V or 38 VYellow-yellow leads, nameplate values inconsistent
Output 2AC 0 V to 36 V or 38 VBlue-blue leads, nameplate values inconsistent
CoreGrain-oriented silicon steel, seamlessGrade not stated
WindingOxygen-free copper, radial windingWire diameter not stated
InsulationTransparent high-voltage film wrappingThermal class not stated
Thermal protection130°C thermal cutoffOnly protection measure noted
DimensionsNot statedNo drawing or dimensions noted

13. Applications

The following uses are the application directions indicated by the product literature, noting why a toroidal transformer of this power rating suits each scenario. These descriptions indicate the product's sales positioning, not certification of a specific construction.

Power amplifier supply. The device in the photo is mounted on the amplifier base plate, supplying the energy storage filter capacitor bank.

Preamplifier and DAC supply. Used where leakage flux and mechanical noise matter more than power rating.

Powered speakers. One transformer is housed in the speaker cabinet, with rectifier and capacitors on the amplifier board.

Studio and instrument amplifiers. Two secondary windings provide dual supply rails, with a 130°C thermal cutoff as a thermal protection backup.

Industrial and control panels. Suitable for compact cabinets where the low profile and bolt mounting fit well.

Full-series OEM customisation. The same construction covers 50 VA to 1000 VA, single or dual output, manufactured to order.

14. Ordering

First provide the required supply rail parameters, then specify the values. A valid enquiry should state: mains voltage and frequency, secondary voltage and current required for each winding, whether the two windings are used as independent rails or in series, ambient temperature and mounting method. Please confirm whether the quotation refers to a 36 V or 38 V secondary, and request the following parameters because they are not published: diameter, height, weight, bolt thread specification, base plate mounting hole diameter, current per winding, voltage regulation and test voltage. If the required product is close to this model, start your enquiry with RY-800VA and list the differences.

Compliance note: The panel shows CCC, CE, RoHS and UL marks and states that all four cover the part. No certificate numbers, standard references or test reports accompany the marks, and the UL mark does not show 'Recognized'. This is presented as marks and statements only, not as verified certification. Power transformers are safety-critical components, so be sure to request certificates and reports that meet your product's required standards before finalising the design.

Scope note for this page. Model RY-800VA, 800 VA rating, red-red leads as 220 V 50 Hz primary, yellow-yellow and blue-blue leads as two secondaries, panel readings of 36 V and 38 V, 130°C cutoff temperature, oxygen-free copper radial winding, grain-oriented silicon steel core, transparent insulation wrap, centre bolt with rubber washer, base plate, 50 VA to 1000 VA range, packaging description, four certification marks, and analyzer readings of 229.7 V, 0.151 A, 34.70 W and 0.996 power factor are transcribed from twelve supplier panels. Diameter, height, weight, bolt thread, hole diameter, current per winding, voltage regulation, efficiency, no-load current, temperature rise, insulation class, dielectric test voltage, lead length and certificate numbers are absent from the original material and are left blank rather than estimated. The 4% figure is the arithmetic result based on the published rating and bench reading, and is noted. All twelve supplier images are used on this page, ten in the gallery and two embedded.

Brand/Manufacturer: ZXY, Shenzhen Zhixiangyuan Electronics Co., Ltd. http://www.zxycoil.com

Specifications

RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount · Specifications
型号RY-800VA
型号(2)RY-800VA
热保护130摄氏度切断
输出2交流0V至36V,蓝色引线
输出1交流0V至36V,黄色引线
类型环形音频电源变压器
额定功率800 VA
制造商深圳市智祥源电子有限公司
输入交流220V,50Hz
安装方式中心螺栓带橡胶垫
品牌ZXY

Only supplied parameters are shown. Please confirm any unlisted electrical performance, test conditions, tolerances and customization options with our engineers. The final specification sheet takes precedence.

Product Images & Drawings

View the available product images and drawings below. Click to open the original. Customized products are subject to the agreed specifications and drawings.

RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount — Product Images & Drawings1
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount · 1View Original
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount — Product Images & Drawings2
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount · 2View Original
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount — Product Images & Drawings3
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount · 3View Original
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount — Product Images & Drawings4
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount · 4View Original
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount — Product Images & Drawings5
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount · 5View Original
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount — Product Images & Drawings6
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount · 6View Original
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount — Product Images & Drawings7
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount · 7View Original
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount — Product Images & Drawings8
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount · 8View Original
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount — Product Images & Drawings9
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount · 9View Original
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount — Product Images & Drawings10
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount · 10View Original
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount — Product Images & Drawings11
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount · 11View Original
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount — Product Images & Drawings12
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount · 12View Original
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount — Product Images & Drawings13
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount · 13View Original
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount — Product Images & Drawings14
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount · 14View Original
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount — Product Images & Drawings15
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount · 15View Original
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount — Product Images & Drawings16
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount · 16View Original
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount — Product Images & Drawings17
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount · 17View Original
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount — Product Images & Drawings18
RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount · 18View Original

Downloads

No specification sheet has been uploaded for this model yet. Use the inquiry form below to request parameters, dimension drawings or sample information.

Selection & Customization Requirements

To help confirm a suitable model and specification, please provide:

  • Your equipment, application, operating environment and temperature range.
  • As applicable: inductance, turns ratio or impedance, operating frequency, voltage, current and insulation requirements.
  • Size limits, mounting method, pin spacing, and any existing drawings or reference samples.
  • Sample quantity, estimated order volume and desired delivery date.
Request Specifications / Selection Support

Frequently Asked Questions

Common procurement questions about RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount.

What is RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount?

RY-800VA is the model number on the nameplate, which carries all identifying information for this component: the primary is red leads, AC 220 V 50 Hz; secondaries are 0 V to 38 V between yellow-yellow wires, and 0 V to 38 V between blue-blue wires; it carries a 130 degrees C thermal marking and a date stamp. The same nameplate also bears CCC, CE and WEEE marks and a double insulation symbol. No drawing is included in the material, so the nameplate serves as the datasheet.

Can RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount be customized to our specifications?

Yes. Shenzhen ZhiXiangyuan Electronics Co., Ltd. provides OEM/ODM services. Inductance, turns ratio, current rating, core material, size and terminal style can all be customized according to your drawings or samples.

What is the MOQ and lead time for RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount?

MOQ is negotiable based on the specific model and order quantity. Typical lead time is 1-3 weeks for standard items and 2-4 weeks for customized orders. Contact our sales team for an exact quotation.

Do you provide samples of RY-800VA 800VA Toroidal Audio Power Transformer AC 220V 50Hz Dual Secondary Centre Bolt Mount?

Yes, samples are available for evaluation before bulk orders. Please send us your requirements and shipping details to request samples.

What is the model number of this product?

The model number is RY-800VA. Custom model numbers can be assigned for OEM orders.

Send Us a Message