Professional Transformer & Inductor Manufacturer
Current Transformer

ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm

ModelZXY-CT226ACategoryCurrent Transformer

ZXY-CT226A Precision AC Current Transformer, part of the GL-CT226AB series, rated input 30 A AC, available with 1000:1 and 2000:1 turns ratios, PCB mounting. Epoxy resin encapsulated housing with a Φ5 mm primary through-hole and two secondary pins, body dimensions: height 19 mm, width 18 mm, depth 10.2 mm.

型号
ZXY-CT226A
型号(2)
ZXY-CT226A
初级
Φ5 mm 穿心母排

View all specifications →

Description

1. Product Name

ZXY-CT226A Precision AC Current Transformer, GL-CT226AB series, rated input 30 A AC, available with 1000:1 and 2000:1 turns ratios, PCB mounting. Epoxy resin encapsulated housing with a Φ5 mm primary through-hole and two secondary pins, body dimensions: height 19 mm, width 18 mm, depth 10.2 mm.

Six views: front, rear, side, bottom, and two isometric views of the same package
Six views: front, rear, side, bottom, and two isometric views of the same package

Encapsulation. The six views show the same molded part: an arched body with a through-hole penetrating the flat surface, a flange at the bottom, and two pins below the flange. No adjustment components, no terminals – the shape is the entire mechanical interface, which is why a 0.5 mm dimensional tolerance is the only tolerance the pad must absorb.

The arched section is the core window seen from the end. The core is toroidal, and the central hole is the primary: the wire passes through the opening, so the primary is a single turn of any cable passing through, while the secondary carries the multi-turn winding that steps the current down.

2. Characteristics

Through-hole primary. The conductor being measured passes through the Φ5 mm center hole, and the secondary winding is brought out to two PCB pins, so the device never connects to the circuit it measures.

Rated input 30 A AC. Rated at 30 A AC on 50/60 Hz supplies, it can cover main circuit branches or motor lines without placing a shunt in series with the path.

Two turns ratios in the same body. The 1000:1 ratio corresponds to 30 mA AC output, and the 2000:1 to 15 mA AC output, so the metering input can be matched to the required resolution.

Phase error of 5 arc minutes or better. Maintained under the load specified in the datasheet for each ratio, this makes the device suitable not only for presence detection but also for power measurement.

Linearity of 0.2% and 0.1%. The 2000:1 ratio is the more accurate of the two, and both values are measured at 25 °C over the linear range shown in the table.

GL-CT226AB series card: rated input 30 A AC, turns ratios 1000:1 and 2000:1, phase error ≤5 arc minutes
GL-CT226AB series card: rated input 30 A AC, turns ratios 1000:1 and 2000:1, phase error ≤5 arc minutes

The series card lists the three key parameters that determine product value side by side: 0.1% linearity error, 5 arc minute phase error, and 30 A AC rated input, with both turns ratios available. Please interpret the linearity values in conjunction with the table: 0.1% corresponds to the 2000:1 ratio, while the 1000:1 ratio is specified as 0.2%, and 0.1% is also the accuracy class printed on the housing.

3. Advantages

Epoxy resin encapsulation. The core and winding are encapsulated in epoxy resin, providing moisture sealing and fixing the components mechanically and electrically.

Flame-retardant housing. The housing meets UL94-V0 rating, which is typically required for power-side components.

Insulation resistance above 1000 MΩ. Measured under normal conditions, supported by a 4 kV dielectric strength test at 50 Hz for 1 minute.

Compact PCB mounting body. Dimensions are 19 mm × 18 mm × 10.2 mm with a pin spacing of 12.0 mm, so it stands on the circuit board rather than being placed on the board side through terminals.

Tolerance controlled to 0.5 mm. The dimensional tolerance is 0.5 mm, which is required for reliable machine placement of molded parts.

Custom designs. If the two standard turns ratios are not suitable, other ratios and loads can be manufactured on request.

UL94-V0 flame-retardant housing and insulation resistance above 1000 MΩ, matte housing juxtaposed with encapsulated body
UL94-V0 flame-retardant housing and insulation resistance above 1000 MΩ, matte housing juxtaposed with encapsulated body
Labels and two turns ratios: Φ5 mm primary hole, two secondary pins, epoxy encapsulation, UL94-V0 housing
Labels and two turns ratios: Φ5 mm primary hole, two secondary pins, epoxy encapsulation, UL94-V0 housing

The two labeled views show the same part before and after encapsulation: on the left is the matte molded part, on the right the cured epoxy filled window, with the two secondary pins as the only metal parts extending from the body. The dimension panel below gives the same 19 mm, 18 mm, 10.2 mm, and Φ5 mm dimensions as the outline drawing, while the two ratio cards repeat the 46 ± 8 Ω and 147 ± 15 Ω DC resistances that distinguish them.

4. Applications

AC current measurement and monitoring in power supplies. Reads the power supply's own output current without breaking the conductor.

Energy meters and power measurement circuits. Phase error and linearity are the two key parameters determining whether a measurement-grade device is adequate here.

Motor and load current sensing. Rated input of 30 A AC and linear range of 0-60 A AC for the 2000:1 ratio means startup surges can remain in the linear range.

Protection, control, and instrumentation equipment. The isolated, scaled current replica is exactly the signal form that protection relays or control inputs are designed to accept.

Primary conductor passing through the Φ5 mm aperture, next to a unit already mounted on a circuit board
Primary conductor passing through the Φ5 mm aperture, next to a unit already mounted on a circuit board
Mounted on an AC current measurement board, picking up the signal through two secondary pins
Mounted on an AC current measurement board, picking up the signal through two secondary pins
Three-quarter view of a single unit on a white background, showing the Φ5 mm aperture and two secondary pins
Three-quarter view of a single unit on a white background, showing the Φ5 mm aperture and two secondary pins

The first view shows the part in both operating states: one unit passes the primary conductor through the aperture with nothing else connected, while another unit is mounted in place via its two pins. The second view places it on an AC measurement board, with the secondary winding directly connected to the sampling resistor and signal conditioning circuitry immediately adjacent.

5. Application Specifications

The following specifications are the declared data for this series at 25 °C: product data, electrical parameter tables for each specification, outline and mechanical data, and terminal assignments with their operating rules.

5.1 Product Specifications

ItemParameter Value
Model/Ordering CodeZXY-CT226A
SeriesGL-CT226AB
Specification CategoryGL-CT226A1.0B, 1000:1 | GL-CT226A2.0B, 2000:1
Product TypePrecision AC current transformer, through-hole primary
Rated Input Current30 A AC, 50/60 Hz
Turns Ratio1000:1 or 2000:1
Rated Output Current30 mA AC or 15 mA AC
Voltage Class0.66/0.72 kV
Dielectric Strength4 kV, 50 Hz, 1 minute
Insulation Resistance>1000 MΩ (under normal conditions)
Flame Retardant RatingUL94-V0
EncapsulationEpoxy resin encapsulation
PrimaryThrough-hole bus, Φ5 mm
Secondary2 PCB pins, Φ0.9 mm, length 4 ± 1 mm
MountingPCB through-hole mounting
Operating Temperature−40 °C to +70 °C
Reference Temperature25 °C

5.2 Electrical Specifications, Both Specifications, 25 °C

Both specifications are rated for 30 A AC input (50/60 Hz) and share the same voltage class, dielectric strength, and temperature range. They differ in turns ratio, output current, phase error sampling resistor, linear range, linearity, DC resistance, and net weight.

ParameterGL-CT226A1.0BGL-CT226A2.0BUnit
Rated Input Current3030A (AC)
Rated Output Current3015mA (AC)
Turns Ratio1000:12000:1Ratio
Phase Error≤5 (RL = 50 Ω)≤5 (RL = 100 Ω)arc minutes (′)
Linear Range0-36 (RL = 20 Ω)0-60 (RL = 100 Ω)A (AC)
Linearity0.20.1%
DC Resistance46 ± 8147 ± 15Ω
Net Weight8.49g
Dimensional Tolerance0.50.5mm
The differences between the two specifications are not limited to the turns ratio; they are not interchangeable in a circuit. The GL-CT226A1.0B offers a 1000:1 turns ratio, outputs 30 mA AC, has a linearity of 0.2%, and a rated range of 0-36 A AC (20 Ω sampling resistor); the GL-CT226A2.0B offers a 2000:1 turns ratio, outputs 15 mA AC, has a linearity of 0.1%, and a rated range of 0-60 A AC (100 Ω sampling resistor). The phase error is specified with a 50 Ω sampling resistor for the first and 100 Ω for the second, so the sampling resistor is part of the specification, not a freely selectable parameter.

5.3 Outline and Mechanical Data

ParameterSpecification
Total Height19 mm
Total Width18 mm
Body Depth10.2 mm
ApertureΦ5 mm
Pin Spacing12.0 mm
Pin Length4 ± 1 mm
Pin DiameterΦ0.9 mm
Dimensional Tolerance0.5 mm
MountingPCB through-hole mounting
Outline drawing, unit mm: height 19 mm, width 18 mm, body depth 10.2 mm, Φ5 mm aperture, pin length 4 ± 1 mm
Outline drawing, unit mm: height 19 mm, width 18 mm, body depth 10.2 mm, Φ5 mm aperture, pin length 4 ± 1 mm
The outline dimensions are height 19 mm, width 18 mm, depth 10.2 mm, Φ5 mm primary aperture, pin spacing 12.0 mm, and pin length 4 ± 1 mm. Dimensional tolerance is 0.5 mm. Pin diameter is Φ0.9 mm. The source document does not provide pad or drill dimensions; these should be obtained from the recommended pad pattern rather than this table.

5.4 Terminals and Connections

TerminalFunctionCurrent Direction
P1Primary inputPrimary current flows into the transformer
P2Primary returnPrimary current returns from the transformer
S1Secondary outputSecondary current flows out to external circuit
S2Secondary returnSecondary current returns to the transformer

Primary current flows in through P1 and returns through P2; secondary current flows out from S1 and returns through S2. P1 and P2 are the ends of the conductor passing through the center hole, not pins on the device – the only metal terminals on the housing are the two secondary pins.

Current transformers must never be operated with an open secondary. Without a load, the secondary cannot cancel the primary flux, and the voltage across the two pins will rise until the winding or insulation fails. For the same reason, no fuse may be installed in the secondary circuit – a blown fuse is equivalent to an open circuit. Connect a load to S1 and S2 before energizing the primary, and keep it connected until the primary is de-energized.

6. Quality and Test Assurance

All parameters are specified at an ambient temperature of 25 °C. Test items include rated input and output current, turns ratio, phase error, linearity, DC resistance, and dielectric withstand.

Test ItemSpecificationCondition
Rated input and output currentInput 30 A AC; output 30 mA AC or 15 mA AC50/60 Hz
Turns ratio1000:1 or 2000:1Per production batch
Phase error≤5 arc minutesRL 50 Ω or 100 Ω
Linearity0.2% or 0.1%25 °C
DC resistance46 ± 8 Ω or 147 ± 15 Ω25 °C
Dielectric withstand4 kV50 Hz, 1 minute
Insulation resistance>1000 MΩNormal conditions

The dielectric test is 4 kV at 50 Hz for 1 minute, with an operating temperature range of −40 °C to +70 °C. Insulation resistance is above 1000 MΩ under normal conditions, which is what the encapsulated structure is intended to maintain.

This page references the structural, dimensional, electrical, and test data declared by the datasheet at 25 °C. The datasheet does not declare minimum order quantity or price, so neither is provided here; net weight is referenced as two values listed according to two production batches, not a single value. The document notes that CCC, CE, RoHS, and UL marks appear on the product artwork, but no certificate numbers are provided for any of them, so this page does not claim any certification and does not use artwork with mark bars. The ordering code is ZXY-CT226A; the series name and the mark printed on the housing are GL-CT226AB, and the two production batch codes are GL-CT226A1.0B and GL-CT226A2.0B. Please quote the ordering code when ordering, and the production batch code when a specific turns ratio is required.

Brand/Manufacturer: ZXY, Shenzhen Zhi Xiang Yuan Electronics Co., Ltd. http://www.zxycoil.com

Specifications

ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm · Specifications
型号ZXY-CT226A
型号(2)ZXY-CT226A
初级Φ5 mm 穿心母排
输入电流30 A 交流(50/60 Hz)
介质耐压4 kV,50 Hz,1分钟
系列GL-CT226AB
输出电流30 mA 交流或 15 mA 交流
外形尺寸19 x 18 x 10.2 mm
安装方式PCB 穿心,2个引脚
匝数比1000
产品类型精密交流电流互感器

Only supplied parameters are shown. Please confirm any unlisted electrical performance, test conditions, tolerances and customization options with our engineers. The final specification sheet takes precedence.

Product Images & Drawings

View the available product images and drawings below. Click to open the original. Customized products are subject to the agreed specifications and drawings.

ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm — Product Images & Drawings1
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm · 1View Original
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm — Product Images & Drawings2
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm · 2View Original
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm — Product Images & Drawings3
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm · 3View Original
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm — Product Images & Drawings4
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm · 4View Original
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm — Product Images & Drawings5
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm · 5View Original
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm — Product Images & Drawings6
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm · 6View Original
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm — Product Images & Drawings7
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm · 7View Original
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm — Product Images & Drawings8
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm · 8View Original
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm — Product Images & Drawings9
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm · 9View Original
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm — Product Images & Drawings10
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm · 10View Original
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm — Product Images & Drawings11
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm · 11View Original
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm — Product Images & Drawings12
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm · 12View Original
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm — Product Images & Drawings13
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm · 13View Original
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm — Product Images & Drawings14
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm · 14View Original
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm — Product Images & Drawings15
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm · 15View Original
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm — Product Images & Drawings16
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm · 16View Original
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm — Product Images & Drawings17
ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm · 17View Original

Downloads

No specification sheet has been uploaded for this model yet. Use the inquiry form below to request parameters, dimension drawings or sample information.

Selection & Customization Requirements

To help confirm a suitable model and specification, please provide:

  • Your equipment, application, operating environment and temperature range.
  • As applicable: inductance, turns ratio or impedance, operating frequency, voltage, current and insulation requirements.
  • Size limits, mounting method, pin spacing, and any existing drawings or reference samples.
  • Sample quantity, estimated order volume and desired delivery date.
Request Specifications / Selection Support

Frequently Asked Questions

Common procurement questions about ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm.

What is ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm?

ZXY-CT226A Precision AC Current Transformer, part of the GL-CT226AB series, rated input 30 A AC, available with 1000:1 and 2000:1 turns ratios, PCB mounting. Epoxy resin encapsulated housing with a Φ5 mm primary through-hole and two secondary pins, body dimensions: height 19 mm, width 18 mm, depth 10.2 mm.

Can ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm be customized to our specifications?

Yes. Shenzhen ZhiXiangyuan Electronics Co., Ltd. provides OEM/ODM services. Inductance, turns ratio, current rating, core material, size and terminal style can all be customized according to your drawings or samples.

What is the MOQ and lead time for ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm?

MOQ is negotiable based on the specific model and order quantity. Typical lead time is 1-3 weeks for standard items and 2-4 weeks for customized orders. Contact our sales team for an exact quotation.

Do you provide samples of ZXY-CT226A Precision AC Current Transformer, 30 A Input, 1000:1 / 2000:1, Φ5 mm Through-Hole Primary, PCB Mounting, 19 x 18 x 10.2 mm?

Yes, samples are available for evaluation before bulk orders. Please send us your requirements and shipping details to request samples.

What is the model number of this product?

The model number is ZXY-CT226A. Custom model numbers can be assigned for OEM orders.

Send Us a Message

Tell us your requirements and our engineers will reply within 24 hours.